Skip to main content
Engineer levelling the sub-base before laying slabs for a new oil tank base

FAQs

Oil Tank Questions, Answered

Costs, regulations, bunding, separation distances, water contamination and servicing intervals. These are the questions our engineers get asked on site every week, answered properly.

Replacing Your Tank

Typically single skin tanks last around 15 years depending on quality and conditions. Bunded tanks would typically last around 25 years also depending on quality and conditions. Bunded tanks last a lot longer because they have a secondary protective layer. If you see any cracks or major wear and tear on your oil tank please contact us immediately for a free inspection.

The clearest signs are rust, blistering or weeping seams on a steel tank; cracks, crazing or bulging on a plastic tank; oil staining or a strong smell around the base; a cracked, sinking or undersized base; and repeated boiler lockouts or blocked filters caused by water and sludge. If you have any of those, book a free inspection rather than waiting for a failure.

Most oil tanks can usually be installed in a day; this will depend on the size of the tank and what work needs to be done.

Yes, there are tanks that are manufactured for the sole purpose of being kept underground.

Our team carefully drain and clean old oil tanks ready for a licensed company to pick them up for recycling.

It depends on capacity, plastic or steel, how much groundwork the base needs, and the oil line run. Rather than quote a range that turns out to be wrong for your site, we survey free of charge and give you a fixed written price covering tank, base, fittings, removal and recycling of the old tank, and recommissioning.

Yes, finance plans are available; please contact a member of our staff to find out more and apply.

Regulations and Compliance

A bunded tank is a double-walled tank; the outer layer is designed to hold 110% of the inner tank's capacity in case the inner tank was to leak or be overfilled.

A single skin tank is a tank with only one protective layer, so if this tank was to crack or split it could cause contamination.

A bunded tank would be required if the location of where the new oil tank is going does not comply with OFTEC regulations for environmental safety.

There are many rules and regulations regarding oil tank location. The rules and regulations can be found on the OFTEC page on our website. If you need more information then please contact one of our team.

For a domestic tank: 1.8 metres from non-fire-rated buildings, eaves, doors and windows; 1.8 metres from liquid fuel appliance flue terminals; 760mm from non-fire-rated boundaries such as timber fencing; and 600mm from screening or foliage. Where those distances cannot be achieved, a 30-minute fire-rated barrier can be used instead.

Domestic tanks up to 3,500 litres are normally permitted development, so planning permission is not usually needed. Listed buildings, conservation areas, National Parks and larger commercial installations are the usual exceptions. Building Regulations Part J applies regardless, which is why the work must be certified by an OFTEC registered engineer.

To get an OFTEC certificate, an OFTEC registered engineer would have to do a risk assessment and issue you with one if it is compliant.

All bases are required to be made from concrete, be level and exceed the oil tank on all edges by 300mm and they are required to be 100mm thick.

Servicing, Water and Contamination

As part of your annual boiler service your oil tank should be checked for any fractures / cracks, clean filters, build-up of water in the tank and to make sure the tank meets Building Regulations.

Mostly condensation. Warm damp air enters through the vent, then condenses on the cold inner walls and runs to the bottom. Perished fill cap seals, missing vent caps and poorly bedded lids let rainwater in directly. Because water is denser than kerosene it sits at the base, where the outlet and the steel floor are.

If you have water in your oil tank we advise you to turn your boiler off and ring us right away so one of our team can come out to you and drain the oil from your tank and remove all contaminated water, clean out the oil lines and return the clean oil back into the tank.

A bacterial and fungal growth that lives at the fuel-water interface in the bottom of a tank. It produces a dark sludge that blocks filters and nozzles, and its by-products are acidic, so it accelerates corrosion of the tank floor. Removing the water is the only reliable long-term fix.

Yes. We pump the oil into our own holding tanks, filter out water and sediment, clean the tank, then return the good oil. Very little usable fuel is lost.

Working with Us

We are based in Market Rasen, Lincolnshire, and cover Lincolnshire, North and North East Lincolnshire, Nottinghamshire, Derbyshire, South Yorkshire, North Yorkshire, the East Riding of Yorkshire, Staffordshire, Leicestershire, Rutland and Cambridgeshire. If you are just outside that area, call us anyway, because we travel further for larger and commercial jobs.

Yes. An OFTEC registered engineer visits, inspects the tank, base, oil line and siting, and issues a fixed written quotation. There is no charge and no obligation.

This is an emergency situation and we strongly advise you to call our emergency line (found on our home page) right away.

Yes, 24 hours a day, seven days a week on 07508 705738. If a tank is leaking, contain what you can safely, keep people and pets away, do not hose it down or wash it into a drain, and call us.

Yes. Alongside domestic heating oil tanks we install and service bulk kerosene, diesel, gas oil, HVO and AdBlue storage for farms, estates, haulage yards and commercial premises, built to the Control of Pollution (Oil Storage) Regulations.

Yes. We carry full public liability insurance, and our engineers are OFTEC registered for the categories of work they carry out. Documentation is available on request.

Get a Free, No-Obligation Site Survey

An OFTEC registered engineer will inspect your tank, base and oil line, then give you a fixed written quote for the whole job. The survey costs you nothing and you are under no obligation to book the work.